Installation Guide
Table Of Contents
- CCU100 and Repeater100 Installation Guide
- Important Safety and Compliance Information
- 1 Before You Begin
- 2 CCU/Repeater Basics
- 3 Planning a CCU/Repeater Installation
- 4 Installing the Collector or Repeater
- 5 Battery Care and Maintenance
- A Detailed Collector or Repeater Specifications
- B Port and Protocol Requirements
- C Status and Diagnostics
- D Changing the Repeater Password
- E Antenna Line Sweeps Procedure
- Anritsu Site Master Calibration
- Testing on a Network Device with a Remotely-Mounted 915 MHz Antenna
- Understanding Party Responsibilities
- Itron ChoiceConnect Antenna and Line Sweep Test Form
- Itron ChoiceConnect 915 MHz Antenna Specifications
- Typical Coaxial Cable Specification Summary Table
- Sample Sweeps Output
- F Grounding Specifications
- Understanding Grounding and Bonding
- Exterior Grounding System Design for Concentrators
- Equipment Buried Ground Ring
- Chemical Ground Rod Installation
- Itron Concentrator Equipment
- Installing Coax Ground Kits
- Collector Sites with Indoor Itron TCU / CCU Equipment
- Grounding Rooftop Network Devices
- Down Conductor Installation
- Cold Water Pipe Option
- Building Steel Option
- Antenna and Coax Grounding - Rooftops
- Grounding antennas on rooftops
- Cable Tray Grounding
- Water Tower Grounding
- New Wooden and Concrete Antenna Poles
- Equipment Shelter Grounding
- Repeaters on Communication Tower Sites
- Repeaters on Rooftops
- Multiple Story Site Ground System
- Down Conductors Installation - Building / Shelter Penetrations
- Down Conductors Installation - Limits of Bend Radius
- Down Conductors Installation Connection Methods
- Cable Entrance Facilities
- Clamp-On Ground Resistance Testing
- Understanding Party Responsibilities
Fixed Network server to server traffic (intranet)
Source
address
Source
port
Destination
address
Destination
port
Protocol Required
for
operation
Purpose
Fixed
Network
database
server
Any Fixed
Network NPA
server
135-139
or 445
TCP,UDP
or
TCP,UDP
Yes Data file export if
NPA database is
on a different
server than NCE
(UNC shares).
Refer to Microsoft
documentation for
details.
Microsoft file
sharing SMB uses
ports 135-139.
Direct-hosted SMB
without NetBIOS
uses port 445.
Fixed
Network
database
server
Any Fixed
Network web
server
443 HTTPS Yes URL validation.
Fixed
Network
database
server
Any ISM server 443** HTTPS Optional Encryption
Workstation to server traffic
Source
address
Source
port
Destination
address
Destination
port
Protocol Required
for
operation
Purpose
Fixed
Network
workstation
Any Fixed Network
database server
1433** MSSQL Yes Database
access for
Collector
Configuration
Application
(CCA) (Fixed
Network 4.0
only).
Fixed
Network
workstation
Any Fixed Network
database server
80
443
HTTP
HTTPS
Yes Network
Administration
Application
(NAA), Network
Web
CCU100 and Repeater100 Installation Guide B Port and Protocol Requirements
12 February 2021 815-0491-00 Itron, Inc. Page 85 of 133