Installation Guide
Table Of Contents
- CCU100 and Repeater100 Installation Guide
- Important Safety and Compliance Information
- 1 Before You Begin
- 2 CCU/Repeater Basics
- 3 Planning a CCU/Repeater Installation
- 4 Installing the Collector or Repeater
- 5 Battery Care and Maintenance
- A Detailed Collector or Repeater Specifications
- B Port and Protocol Requirements
- C Status and Diagnostics
- D Changing the Repeater Password
- E Antenna Line Sweeps Procedure
- Anritsu Site Master Calibration
- Testing on a Network Device with a Remotely-Mounted 915 MHz Antenna
- Understanding Party Responsibilities
- Itron ChoiceConnect Antenna and Line Sweep Test Form
- Itron ChoiceConnect 915 MHz Antenna Specifications
- Typical Coaxial Cable Specification Summary Table
- Sample Sweeps Output
- F Grounding Specifications
- Understanding Grounding and Bonding
- Exterior Grounding System Design for Concentrators
- Equipment Buried Ground Ring
- Chemical Ground Rod Installation
- Itron Concentrator Equipment
- Installing Coax Ground Kits
- Collector Sites with Indoor Itron TCU / CCU Equipment
- Grounding Rooftop Network Devices
- Down Conductor Installation
- Cold Water Pipe Option
- Building Steel Option
- Antenna and Coax Grounding - Rooftops
- Grounding antennas on rooftops
- Cable Tray Grounding
- Water Tower Grounding
- New Wooden and Concrete Antenna Poles
- Equipment Shelter Grounding
- Repeaters on Communication Tower Sites
- Repeaters on Rooftops
- Multiple Story Site Ground System
- Down Conductors Installation - Building / Shelter Penetrations
- Down Conductors Installation - Limits of Bend Radius
- Down Conductors Installation Connection Methods
- Cable Entrance Facilities
- Clamp-On Ground Resistance Testing
- Understanding Party Responsibilities
Specification WAN-3G WAN-3G/4G WAN-3G/4G
Mounting Direct or Remote Direct Remote
Itron part number MSE-0259-001 MSE-0439-001 MSE-0784-001
Frequency range 806-896 MHz
1850-1900 MHz
698-894 MHz
1710-2170 MHz
698-960 MHz
1710-2170 MHz
Maximum gain 2.15 dBi (806-896)
5.15 dBi (1850-1900)
2 dBi 4.5 dBi
Power rating 100 W 25 W 150 W
Polarization Vertical
Omnidirectional
Vertical
Omnidirectional
Vertical
Omnidirectional
Impedance 50 ohms 50 ohms 50 ohms
Termination N-Female N-Male N-Female
Overall dimensions 13.8” L x 1.3” D 5.1 ” L x 1.2” D 12.6” L x 2.8” D
Approved only for the following
HVINs:
See note below.
CCU100
CCU100R
CCU100A
CCU100RA
TowerCCU
TowerCCUA
CCU100B
CCU100C
CCU100RB
CCU100RC
TowerCCUB
Note: Using a model of WAN antenna on a CCU or Repeater HVIN that is not on the
approved list will cause the CCU or Repeater to be out of regulatory compliance.
Innovation, Science, and Economic Development Canada (ISED) Conformity
This radio transmitter has been approved by Innovation,
Science and Economic Development Canada (ISED) to
operate with the antenna types listed previously with the
maximum permissible gain and required antenna
impedance for each antenna type indicated. Antenna
types not included in this list, having a gain greater than
the maximum gain indicated for that type, are strictly
prohibited for use with this device.
Le présent émetteur radio est conforme aux CNR
d'Industrie Canada pour fonctionner avec les types
d'antenne énumérés ci-dessus et ayant un gain
admissible maximal et l'impédance requise pour
chaque type d'antenne. Les types d'antenne non
inclus dans cette liste, ou dont le gain est supérieur
au gain maximal indiqué, sont strictement interdits
pour l'exploitation de l'émetteur.
12 February 2021 815-0491-00 Itron, Inc. Page 7 of 133