Installation Guide
Table Of Contents
- CCU100 and Repeater100 Installation Guide
- Important Safety and Compliance Information
- 1 Before You Begin
- 2 CCU/Repeater Basics
- 3 Planning a CCU/Repeater Installation
- 4 Installing the Collector or Repeater
- 5 Battery Care and Maintenance
- A Detailed Collector or Repeater Specifications
- B Port and Protocol Requirements
- C Status and Diagnostics
- D Changing the Repeater Password
- E Antenna Line Sweeps Procedure
- Anritsu Site Master Calibration
- Testing on a Network Device with a Remotely-Mounted 915 MHz Antenna
- Understanding Party Responsibilities
- Itron ChoiceConnect Antenna and Line Sweep Test Form
- Itron ChoiceConnect 915 MHz Antenna Specifications
- Typical Coaxial Cable Specification Summary Table
- Sample Sweeps Output
- F Grounding Specifications
- Understanding Grounding and Bonding
- Exterior Grounding System Design for Concentrators
- Equipment Buried Ground Ring
- Chemical Ground Rod Installation
- Itron Concentrator Equipment
- Installing Coax Ground Kits
- Collector Sites with Indoor Itron TCU / CCU Equipment
- Grounding Rooftop Network Devices
- Down Conductor Installation
- Cold Water Pipe Option
- Building Steel Option
- Antenna and Coax Grounding - Rooftops
- Grounding antennas on rooftops
- Cable Tray Grounding
- Water Tower Grounding
- New Wooden and Concrete Antenna Poles
- Equipment Shelter Grounding
- Repeaters on Communication Tower Sites
- Repeaters on Rooftops
- Multiple Story Site Ground System
- Down Conductors Installation - Building / Shelter Penetrations
- Down Conductors Installation - Limits of Bend Radius
- Down Conductors Installation Connection Methods
- Cable Entrance Facilities
- Clamp-On Ground Resistance Testing
- Understanding Party Responsibilities
Attaching the Collector or Repeater
You may attach the collector or repeater to a variety of surfaces. See the following sections for
diagrams showing some of the possible configurations.
■
Pipe Mount on page 38
■
Pole Mount on page 40
■
Wall Mount on page 42
■
Davit Arm Mount on page 43
Mounting Hardware
You can adapt the hardware set to mount the collector or repeater in many different locations.
For pole or pipe mounts, the mounting hardware consists of a mounting plate, two brackets, four
bolts, and a set screw.
For a wall mount, use two metal brackets (not shown below), four mounting bolts, nuts, and lock
washers to prepare the collector for mounting. Itron does not supply the hardware necessary to
mount the wall mounting brackets to the wall.
An integrated mounting support on the back of the collector or repeater enclosure slides into the
slot in the center of the mounting bracket. A single set screw is used to lock the collector or
repeater to the mounting bracket. Orientation of the enclosure may be adjusted +/- 16 degrees
horizontal to compensate for different angles.
CCU100 and Repeater100 Installation Guide 4 Installing the Collector or Repeater
12 February 2021 815-0491-00 Itron, Inc. Page 37 of 133