Installation Guide

Table Of Contents
DC Mains Power
DC wiring to the collector or repeater utilizes a two conductor cable. Connect the CCU to a 10A
DC circuit breaker or fuse. Wire the Itron-supplied two conductor cable by attaching the red wire
to a +12V source. Attach the black wire to ground.
Materials Not Provided by Itron
The following materials are not provided by Itron in the collector or repeater kit, but are required
for installation.
Please acquire these items prior to beginning an installation.
Coaxial Cable on page 29 (for remote/external antennas)
Antenna Connectors on page 31
Mounting Hardware on page 31
Coaxial Cable
When you are mounting the remote/external antennas, you must supply coaxial cable to connect
the antenna to the collector or repeater. The required cable size is dependent on the total cable
length and frequency. Coaxial cable also requires proper hoisting grips, ground kits, connectors,
jumpers, hangers, and weather proofing material. Coaxial cable and accessories are not
provided by Itron. You must install and test coaxial cable systems according to the
manufacturer's specifications. Itron recommends using qualified radio installation contractors to
install and test the remote/external antenna system.
All coaxial cable connections must be properly weather-proofed per industry standards unless
otherwise specified. This includes any connections for the antennas and the collector or
repeater.
Refer to the Antenna Line Sweeps Procedure on page 94 to verify that the coax and antenna are
correctly installed.
Remote Mount Standard (5.15 dBi or 5.5 dBi) 915 MHz Antenna on a Standard
CCU/Repeater
When selecting cable for the remote mount 915 MHz antenna on the standard (non-tower)
collector or repeater, total cable loss cannot exceed 1.5 dB to maintain system performance.
Allow 0.1 dB loss for each connector.
CCU100 and Repeater100 Installation Guide 3 Planning a CCU/Repeater Installation
12 February 2021 815-0491-00 Itron, Inc. Page 29 of 133