Installation Guide

Table Of Contents
Make Cable Model Return Loss (dB) VSWR (max.)
Andrew 2-1/4" Heliax LDF12-50 -24.5 1.13:1
Andrew 7/8" Virtual Air AVA5-50 -24.5 1.13:1
Andrew 1-5/8" Virtual Air AVA7-50 -24.5 1.13:1
All Existing Coaxial Feeder All -22.0 1.17:1
Coaxial Cable Path Loss per 100ft
Make Cable Model Velocity Loss/100 @ 2 GHz
Andrew ½" Heliax LDF4-50A 0.88 3.25 dB
Andrew ½" SuperFlex FSJ4-50B 0.81 5.37 dB
Andrew 7/8" Heliax LDF5-50A 0.89 1.86 dB
Andrew 1-1/4" Heliax LDF6-50A 0.89 1.35 dB
Andrew 1-5/8" Heliax LDF7-50A 0.88 1.13 dB
Andrew 2-1/4" Heliax LDF12-50 0.88 0.99 dB
Andrew 7/8" Virtual Air AVA5-50 0.91 1.68 dB
Andrew 1-5/8" Virtual Air AVA7-50 0.92 1.02 dB
Sample Sweeps Output
Return Loss:
CCU100 and Repeater100 Installation Guide E Antenna Line Sweeps Procedure
12 February 2021 815-0491-00 Itron, Inc. Page 101 of 133