User's Manual
Operation: CP1S Version
CENTRON® Polyphase Meter Technical Reference Guide 21
Segment Check
The Segment Check Register addresses applications requiring display scrolling between
kWh and a full segment check. See
Display Timing (on page ) 21 for factory programming
options.
NET DET kWhVA VB VC
Figure 16: Segment Check
Factory Programming Options
Display Timing
The display will scroll between the billing register and the segment check mode based on
the factory programming option.
Option Description
1 7 second billing register display, 1 second blank, 7 second segment
check display (7/7)
2 7 second billing register display, 1 second blank, 1 second segment
check display (7/1)
3 Only the billing register is displayed (7/0)
Digits and Multipliers
The following digit and multiplier settings are available for factory programming:
4 digits x 1 kWh
4 digits x 10 kWh
5 digits x 1 kWh