13. Peel the protective plastic away from the adhes-
ive side of the encoder.
Important: You must do the next two steps exactly as described or the remote ERT module will not
work properly.
14. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown
below, with the adhesive side down. Slide the encoder down along the side of the encoder spacing tool
until it touches the surface of the index (as shown below). Using moderate pressure, hold the encoder
firmly against the index, without moving, for 15 seconds to permanently apply the encoder.
15. Remove the encoder spacing tool and lay the
index on a flat, horizontal surface to reduce strain on
the encoder cable.
16. Program the index reading (with the encoder mounted) into the remote module. Read the remote
module and verify that the reading matches the read programmed into the remote module.
25 July 2019 TDC-1678-005 87
500GERT®Module Installation Guide, RemoteMount Chapter 6 Diaphragm Meter Installation