4-hole front cover gasket:
Itron part number FAB-0014-
003
2-hole front cover gasket:
Itron part number FAB-0014-
002
1-hole front cover gasket:
Itron part number FAB-0014-
001
The Itron replacement index cover gaskets shown below are thicker than standard gaskets and
have a special slot to accommodate the encoder cable. Gaskets are designed for Schlum-
berger/Sprague model 675 and 1000 commercial diaphragm meters. These gaskets may be
incompatible on meters from other manufacturers; alternate cable relief procedures may be
necessary.
Product Mounting Installation Instructions
For remote ERT module mounting with the diaphragm meter, see Mounting on page17.
Diaphragm Meter Mechanical and Wiring Installation
Instructions
Caution: The remote ERT module encoder must be installed at temperatures
between 40° and 95°F to ensure proper adhesion.
25 July 2019 TDC-1678-005 83
500GERT®Module Installation Guide, RemoteMount Chapter 6 Diaphragm Meter Installation