3f. From the Talk to Unit tab, select Setup > Default.
3g. Set the following Default Setup Group parameters:
Enter the desired Cor. Volume Unit parameter.
Set Cor. Pulse Volume to the same number of
units.
For Output Pulse Spacing, enter the largest num-
ber over 285mS that works for your application.
Itron recommends a setting of 350mS.
For Output Pulse Width, enter the largest num-
ber over 28mS that works for your application.
Itron recommends a setting of 40mS.
3h. Click Send at the bottom of the page.
3i. Select Current Page.
ECM2
®
programming
4. Set the ECM2 output pulse spacing to 750ms for operation with the 500G remote ERT module. Out-
put spacing represents an off-time between pulses.
Sensus Meter Installation
This section describes remote OpenWay Riva 500G ERT module installation on compatible
Sensus meters.