Installation Guide
Table Of Contents
- Table of Contents
- 1 Important Safety and Compliance Information
- U.S. and Canadian Patent Numbers
- USA, FCC Part 15 Spectrum Compliance
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Australia, ACMA Spectrum Compliance
- Transportation Classification
- Modifications, Repairs, Installation, and Removal
- Lithium Battery Safety
- Equipment Repairs
- Intrinsic Safety
- Electrostatic Ignition Hazard
- Module Cleaning
- Do Not Drop
- 2 About the OpenWay® Riva Remote 500G ERT® Module
- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Optional Sealant Application Instructions
- 8 Using Gel-cap Connectors to Complete Wiring Connections
configurations. For specialized setup instructions, contact Romet.
1. Remove the ERT module back-
plate (4 screws) to expose the mod-
ule lead wires. The backplate and
screws will be re-installed on the
ERT module later in this procedure
so store them (temporarily) in a
safe, secure place.
2. Insert the lead wires from the module into new 3M gel connectors (Itron part number CON-0023-001)
together with the lead wire from the meter cable (see wiring connections).
3. Crimp the connectors using a 3M hand-held crimping tool.
Important: Use a crimping tool compatible with gel-connectors. Do not use a standard pliers for crimp-
ing gel connectors. For more information, see Using Gel-cap Connectors to Complete Wiring Con-
nections on page93.
Follow the correct wiring configuration for your Romet corrector or meter from the following wiring para-
meters.
Standard AdEM Romet 43-035-40 Cable Wiring
Connection Corrected count Uncorrected count
Romet cable ERT wire Romet cable ERT wire
Pulse Output 1+ Green White Red White
Blue Blue
Pulse Output 1- White Red Black Red
Note: This wiring configuration will not allow a cut cable tamper.
Romet PG9 Pigtail Cable Wiring
Connection Corrected count
Romet cable ERT module
Pulse Output 1+ White White
Pulse Output 1- Red Red
Cut Cable Alarm Green Blue
Note: The pigtail cable is the cable extruding from the back of the AdEM corrector. You must select the
pigtail cable at the time the AdEM corrector is ordered.
25 July 2019 TDC-1678-005 71
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation