Installation Guide

Table Of Contents
Form-A pulse outputs are configurable for compensated or uncompensated volume. The Form-
B output is for alarm output use only.
Connections to the three output pulse channels are completed using loose unterminated wires
(the individual wires from a cable) and gel-connectors. The TCI unit has six unterminated wires
that require six gel-connectors (Itron part number CON-0023-001) to enable pulse connections
to ancillary devices. Loose wires are located inside the gray adapter plate behind the black strain
relief fitting.
Strain relief fitting Honeywell TCI strain relief
tether
Backplate black fitting with
loose cable wires (Honeywell
part number 22-1929)
Completing the connections
1. Connect the remote module to receive TCI pulse readings.
Note: Connect one ERT module/channel to the alarm output if the modules are used on channels A
and B.
2. Remove strain relief fitting by unscrewing it from the gray adapter plate.
Note: Do not remove the fitting's hex nut. Unscrew the entire fitting from the gray adapter plate. A
tether line is secured to the strain relief fitting. When the strain relief fitting is removed, the tether line
pulls the unterminated wires out of the adapter plate for access to the loose wires.
3. Loosen the strain relief fitting hex nut and remove the white plug from the center.
25 July 2019 TDC-1678-005 61
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation