Installation Guide

Table Of Contents
Meter model Meter notes Module
type
Itron
part
number
ERT module notes
Mini-AT
Mini-Max
EC-AT
Pressure and tem-
perature electronic
volume instruments.
Instruments must
have a Form A board.
Form C is NOT sup-
ported. Item #56 Pulse
Scaling Factor must
be 2.0. Item #96 Cor
Vol Display must be 7,
6, 5, or 4 digits (1, 2, 3,
or 4 blanks). Item #115
Output Pulse Code
must be set at 1, 2, or
4. For connection to
Mini-Max only, Item
#115 must be set at 1
or 2. Item 124 wake up
setting on Honeywell
corrector must be set
to 1. Compatible cor-
rector firmware ver-
sions are 2.5020 and
2.73.
500G
remote
ERG-
7000-502
TCI
Temperature Com-
pensating Index. TCI
must have a Form A
board, Form C is NOT
supported. Item #56
Pulse Scaling Factor
must be 2.0. Com-
patible TCI firmware
versions are 1.06,
1,07, and 1.10.
500G
remote
ERG-
7000-502
ERG-
7000-503
The -502 module has a 5' cable
and is used when longer
cabling is required. This mod-
ule will return the cut cable
tamper.
The -503 module has lead
wires designed for use with the
TCI mounting bracket. This
module will return the cut cable
tamper.
25 July 2019 TDC-1678-005 55
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation