D800/D1000 Wiring and Installation
1. Loosen and remove the two screws holding the
mounting brackets to the meter.
2. After the brackets are removed, the pulse out-
put cable is visible.
3. Loosen the cable gland and pull the cable out
until it extends 7.5 to 8" out of the cable gland.
4. Tighten the cable gland. Do not use a pliers or wrench to tighten the cable gland.
5. Rotate one bracket. Route the meter cable through the holes located at the bend of the mounting
brackets.