Installation Guide

Table Of Contents
GE Oil and Gas ES3 or ETC Ordered with the AMR-ready Mounting Kit
1. Score (cut) the cable jacket surrounding the ES3
or ETC wires and carefully remove the cable
jacket to expose the ES3 or ETC wires.
2. Connect the wires to the ERT module. For more information, see GE Oil and Gas Meters With
Pulse Output Wiring on page51.
3. Align the ERT module mounting holes with the
ES3 or ETC bracket mounting holes. Use a T15
Torx screwdriver to insert and tighten the mounting
screws. Tighten the screws in an alternating pat-
tern.
Caution: Upright vertical positioning is critical because:
The 500G series modules are optimized for communication and require upright mounting. Any
other mounting position could result in reduced RF performance.
The remote module tilt tamper sensor requires upright mounting. Any other mounting position may
cause issues with the module's tilt tamper detection.
GE Oil and Gas IMC/W2, or MC2 with the GE Mounting Bracket Kit
Note: This mounting option requires that you follow the installation instructions to attach the
meter maufacturer cable prior to completing this mounting option. This configuration requires
the GE mounting bracket kit available from GE Oil and Gas (GE part number 057783-000).
The kit includes the listed materials.
Quantity Description GE Dresser part number
1 Mounting bracket 015951-000
1 Screw, 8-32 x 7/16-inch 000163-277
2 Screw, 8-32 x 3/4-inch 000163-282
3 Nut, 8-32 012829-005
4 Spacer, #10 053669-001
5 ERT module/bracket mounting
screw, M6 x 20 mm
013444-002
25 July 2019 TDC-1678-005 45
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation