Installation Guide

Table Of Contents
Galvanic Gas Micro Installation
This section describes installation to Galvanic compatible correctors.
Meter model Meter notes Module type Itron part
number
ERT module
notes
GasMicro Elec-
tronic Volume
Corrector
Must select 2
pulses/second
from pulse output
on the output fre-
quency menu.
500G remote ERG-7000-
503
ERT module
cut cable
requires cus-
tomer-supplied
cable capable
of terminating
the module
white and blue
wires at the
meter interface.
Galvanic Installation Overview
Installing the 500G remote ERT module to a Galvanic volume corrector involves four tasks.
1. Programming or verifying that the volume corrector is set up to work with the 500G remote
ERT module. Programming requires a computer communication cable.
2. Connecting the ERT module to the volume corrector. Completing the connections requires a
wire stripper and flat-tip screwdriver sized to tighten the terminal connections on the Gal-
vanic corrector.
3. Mounting the remote ERT module. Select the mounting option appropriate for your install-
ation. See Mounting on page17. Mounting options include:
Wall mount on a sheet metal surface
Pipe mount using the Itron pipe mount kit CFG-0005-003
4. Programming the 500G remote ERT module. For programming information, see Pro-
gramming on page22. Programming requires an Itron ERT programming device (for
example, an FC300SR).
500G remote ERT module configuration with the meter is dependent on your system application.
See the Galvanic corrector product documentation for configuration information.
Galvanic Product Mounting Instructions
See the Galvanic product documentation for custom mounting instructions.
25 July 2019 TDC-1678-005 41
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation