5. Insert the meter cable through the slot on the remote module backplate. Install a cable tie to the
meter cable wire below the meter cable insulation to provide strain relief.
6. Tuck the connectors and cable tie into the remote
module housing. Place backplate on the assembly
and tighten the four backplate screws using a size
T-10 Torx screwdriver.
Important: Verify that the cable tie and gel con-
nectors are inside the module housing and that the
cable extends out of the slot in the backplate. Torque
the backplate mounting screws to 9 to 12 inch-
pounds.
Installing the Remote Module Cable
1. Insert the plug on the cable connected to the 500G
ERT module into the receptacle on the meter adapter
plate.
2. Tighten the threaded collar on the plug onto the American Meter interface receptacle. Verify that the
connection is hand-tight.
25 July 2019 TDC-1678-005 40
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation