Installation Guide
Table Of Contents
- Table of Contents
- 1 Important Safety and Compliance Information
- U.S. and Canadian Patent Numbers
- USA, FCC Part 15 Spectrum Compliance
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Australia, ACMA Spectrum Compliance
- Transportation Classification
- Modifications, Repairs, Installation, and Removal
- Lithium Battery Safety
- Equipment Repairs
- Intrinsic Safety
- Electrostatic Ignition Hazard
- Module Cleaning
- Do Not Drop
- 2 About the OpenWay® Riva Remote 500G ERT® Module
- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Optional Sealant Application Instructions
- 8 Using Gel-cap Connectors to Complete Wiring Connections
1. Trim the remote module wires to 3.5 inches.
2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer)
approximately 1-1/2-inches from the end.
Caution: Do not cut through the individual wire insulation.
3. Separate the meter cable's black, white, and red wires for connection to the remote module. Cut off
the unused wires even with the outer covering (insulation).
Caution: Do not strip the individual wires.
4. Connect the meter cable to the remote module wires using 3M gel-cap connectors following the
American RPM meter to remote module wire connection information and wiring diagrams.
Important: Use a crimping tool compatible with gel-connectors. Do not use standard pliers for crimping
gel-connects. For more information, see Using Gel-cap Connectors to Complete Wiring Con-
nections on page93.
Wire connection information
American meter wire Remote module wire
Black Blue
White White
Red Red
25 July 2019 TDC-1678-005 39
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation