Installation Guide

Table Of Contents
1. Trim the remote module wires to 3.5 inches.
2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer)
approximately 1-1/2-inches from the end.
Caution: Do not cut through the individual wire insulation.
3. Separate the meter cable's black, white, and red wires for connection to the remote module. Cut off
the unused wires even with the outer covering (insulation).
Caution: Do not strip the individual wires.
4. Connect the meter cable to the remote module wires using 3M gel-cap connectors following the
American RPM meter to remote module wire connection information and wiring diagrams.
Important: Use a crimping tool compatible with gel-connectors. Do not use standard pliers for crimping
gel-connects. For more information, see Using Gel-cap Connectors to Complete Wiring Con-
nections on page93.
Wire connection information
American meter wire Remote module wire
Black Blue
White White
Red Red
25 July 2019 TDC-1678-005 39
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation