500G module configuration with the meter is dependent on your system application. See the
Elster American meter configuration information.
Elster American Meter Mounting Instructions
1. Remove the meter's top plate by removing the two 5mm screws and
carefully prying up on the plate. The plate is secured with an O-ring
seal. Remove the O-ring from the plate.
Caution: If the O-ring is damaged during removal, obtain a replace-
ment from Elster American Meter Co.
2. Look into the meter tower and find the meter switch lead and con-
nector (4-pin).
3. If the lead and connector are not visible or cannot be found, remove
the four 5mm mounting screws and the register cover. The meter
switch lead and connector will be visible inside the cover.
4. Feed the lead and connector into the register cover tower.
Note: Save any meter tags. You will re-install them later in the install-
ation process.
25 July 2019 TDC-1678-005 37
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation