Installation Guide

Table Of Contents
the module drive rate settings match those set in the corrector. For example, set the ERT mod-
ule drive rate for 1000 CF when the Eagle Research corrector drive rate is set for 1000 CF.
Elster American meter installation
Some meter manufacturers provide ERT mounting kits and installation procedures for their
meters. If the Elster American RPM meter to the remote ERT module installation instructions are
not available, follow the installation procedures in this section.
Meter model Meter notes Module type Itron part number
10 Metric (10B) Originally
manufactured
by Metric
Metal Works
500G remote ERG-7000-501
Elster American RPM Series
rotary meter
Meter must
have factory-
installed
pulser with
connector out-
put. Purchase
correct cable
interface from
manufacturer.
500G remote ERG-7000-503
Elster American Installation Overview
Installing the 500G remote ERT module to an Elster American meter involves four tasks.
1. Programming or verifying that the meter is set up to work with the 500G remote ERT mod-
ule. Programming requires a computer communication cable.
2. Connecting the ERT module to the meter. Connecting the module to the meter requires:
a wire stripper
a flat-tip screwdriver
3. Mounting the remote ERT module (for mounting information, see Mounting on page17).
Select the mounting option appropriate for your installation. Mounting options include:
Wall mount on a sheet metal surface
Pipe mount using the Itron pipe mount kit CFG-0005-003
Custom Elster American meter mounting option
4. Programming the 500G remote ERT module. For programming information, see Pro-
gramming on page22. Programming requires an Itron ERT programming device (for
example, an FC300SR).
25 July 2019 TDC-1678-005 36
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation