11. Connect the red remote ERT module wire to pin 1 on the K1 terminal port.
12. Twist the remote ERT module's blue and white wires together.
13. Connect the twisted blue and white wires to ter-
minal 2 on the K1 terminal port.
Eagle Research Corrector Programming and Requirements Notes
Important! This information is subject to change without notice. Refer to the Eagle
Research product documentation to verify the most current programming and con-
figuration information for the 500G remote ERT module.
Using Itron 500G remote ERT modules with Eagle Research volume correctors requires Eagle
Research Field Manager software configured with the parameters for your model of Eagle
Research corrector.
Using Eagle Research Field Manager to Change the MPplus Settings
1. Open the Eagle Research Field Manager from
the Start menu or the desktop shortcut.
2. Connect the communications cable from your computer into the MS connector on the side of the
MPplus corrector. After the MS connector is connected, take note of the baud rate displayed on the
front of the corrector.
3. Click Connect on the upper left corner of the
Field Manager window.
25 July 2019 TDC-1678-005 32
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation