For uncorrected reads:
5. Connect:
■
the twisted blue and white wires to ter-
minal 17 on the MPplus terminal block.
■
the red remote ERT module wire to ter-
minal 18 on the MPplus terminal block.
For corrected reads:
6. Connect the twisted blue and white wires to terminal 15 on the MPplus terminal block.
7. Connect the red remote ERT module wire to terminal 16
on the MPplus terminal block.
8. Close and latch the MPplus corrector door.
Connecting to the XARTU Corrector
For XARTU-1 uncorrected reads:
1. Insert the flying leads from the remote ERT mod-
ule into the compression connector on the right of the
XARTU-1 corrector housing.
25 July 2019 TDC-1678-005 30
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation