2. Insert tamper seals into the tamper seal mounting
cups on the remote ERT modules.
3. With the corrector facing forward, align the corrector mounting holes with the index drive mounting
holes.
4. Insert the corrector's mounting screws in the front corrector and index mounting holes. Loosely
tighten the front two mounting screws.
5. Align the inside mounting rail screw holes over the back index and corrector mounting screw holes.
6. Insert the two remaining mounting screws in the corrector bracket mounting holes.
7. Tighten all four mounting screws.
Eagle Research Mechanical and Wiring Installation Instructions
This section provides wiring and connection information for compatible Eagle Research
products. Refer to the instruction for your product type.
Connecting to the MPplus Corrector
1. With the MPplus door open, insert the flying leads from the remote ERT module into the com-
pression connector on the left of the MPplus housing.
2. Pull the lead wires through the compression connector until there is adequate wire to reach the ter-
minal blocks labeled 15, 16, 17, 18, 19, 20, 21, and 22.
3. Tighten the compression connector.
4. Twist the remote ERT module's blue and white wires together.
25 July 2019 TDC-1678-005 29
500GERT®Module Installation Guide, RemoteMount Chapter 5 Specific Meter Manufacturer Installation