Installation Guide
Table Of Contents
- Table of Contents
- 1 Important Safety and Compliance Information
- U.S. and Canadian Patent Numbers
- USA, FCC Part 15 Spectrum Compliance
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Australia, ACMA Spectrum Compliance
- Transportation Classification
- Modifications, Repairs, Installation, and Removal
- Lithium Battery Safety
- Equipment Repairs
- Intrinsic Safety
- Electrostatic Ignition Hazard
- Module Cleaning
- Do Not Drop
- 2 About the OpenWay® Riva Remote 500G ERT® Module
- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Optional Sealant Application Instructions
- 8 Using Gel-cap Connectors to Complete Wiring Connections
Selecting and Installing On a Wall or Flat Vertical
Mounting Location
Carefully select a mounting location free from electrical wires. The mounting location must have
the proper clearance to accommodate the 1-1/2-inch module mounting screws so nothing is dam-
aged by the drill or mounting screws. Use a compatible mounting screw.
1. Drill three pilot holes in the mounting surface. The
drilled pilot holes for the two bottom screws must be
on a horizontal line.
a. 3 inches
b. 1-11/16 inches
c. 3-3/8 inches
2. Screw the top mounting screw into the top pilot
hole drilled in step one, leaving enough of the screw
protruding so the 500G ERT module lug recess on the
back plate slides over the screw head and fits com-
pletely into the lug recess. Make adjustments as
necessary.
3. Install the two bottom mounting screws. Tighten the screws in an alternating pattern to secure the
module firmly in position.
4. Place a new tamper seal over each bottom 500G
ERT module mounting screw as required.
Note: To reduce the risk of cable damage, secure
any excess 500G ERT module cabling with a cable
tie.
25 July 2019 TDC-1678-005 21
500GERT®Module Installation Guide, RemoteMount Chapter 3 Mounting the Remote 500G ERT Module