OpenWay® Riva 500G ERT® Module Installation Guide, Remote Mount TDC-1678-005 INSTALLATION GUIDE
500G ERT® Module Installation Guide, Remote Mount 500G ERT® Module Installation Guide, Remote Mount 25 July 2019 TDC-1678-005 Copyright © 2019 Itron, Inc. All rights reserved. Confidentiality Notice Confidential Information of Itron®, Inc., provided under nondisclosure obligations.
Table of Contents T a b le o fCo n te n ts 1 3 Important Safety and Compliance Information 6 U.S. and Canadian Patent Numbers 6 U.S.
500G ERT® Module Installation Guide, Remote Mount 3 Table of Contents Related Documents 15 Mounting 17 Standard Installation Options 17 Mounting on a Pipe 17 Completing the Installation 4 5 18 Adapter Plate Mounting Positions 20 Selecting and Installing On a Wall or Flat Vertical Mounting Location 21 Programming 22 Standard Configuration 22 Programming the Remote 500G ERT Module 23 Itron Programs and Software Variables 23 Field Deployment Manager (FDM) 23 Mercury X-Blank options
00G ERT® Module Installation Guide, Remote Mount Table of Contents GE Oil and Gas Custom Mounting Options 44 GE Oil and Gas Mechanical and Wiring Installation Instructions 47 GE Oil and Gas Meter Programming and Requirements Notes 53 Honeywell Instrument 500G Installation Honeywell Instrument installation overview 56 Honeywell Product Mounting Instructions 56 Honeywell Mechanical and Wiring Installation Instructions 58 Honeywell Instrument Programming and Requirements 63 Itron Meter Install
1 Important Safety and Compliance Information This section provides important information for your safety and product compliance. U.S. and Canadian Patent Numbers U.S. Patent Numbers ■ 4,614,945 ■ 4,753,169 ■ 4,768,903 ■ 4,799,059 ■ 4,867,700 Canadian Patent Numbers ■ 1,254,949 ■ 1,267,936 ■ 1,282,118 USA, FCC Part 15 Spectrum Compliance This device complies with Part 15 of the FCC Rules.
500G ERT® Module Installation Guide, Remote Mount Chapter 1 Important Safety and Compliance Information instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
500G ERT® Module Installation Guide, Remote Mount Chapter 1 Important Safety and Compliance Information RF Exposure (FCC/ISED) This equipment complies with radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
500G ERT® Module Installation Guide, Remote Mount Chapter 1 Important Safety and Compliance Information Equipment Repairs Warning! Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted. Intrinsic Safety Warning! Substitution of components may impair intrinsic safety.
2 About the OpenWay® Riva Remote 500G ERT® Module Itron remote 500G ERT modules are radio-frequency (RF) IPv6 open standards-based gas modules designed to be read under Itron’s multi-purpose OpenWay Riva Network Mode or by legacy ChoiceConnect Mobile Mode. In OpenWay Riva Network Mode, the 500G ERT module offers firmware download, sub-hourly interval data, and extended data storage. In Mobile Mode, the ERT module operates identical to the 100G DLS Dataglogging ERT module.
500G ERT® Module Installation Guide, Remote Mount Chapter 2 About the OpenWay Riva Remote 500G ERT Module Mobile and Handheld Mode The 500G ERT module transmits a medium-powered RF message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm. In Mobile and Handheld Mode, the expected battery life is 20 years. (Optional) Hard to Read Mode The 500G ERT module transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm.
500G ERT® Module Installation Guide, Remote Mount Chapter 2 About the OpenWay Riva Remote 500G ERT Module Local Auditing Note: Local auditing functionality is dependent on the ERT module's firmware version. For more information, see Device Firmware Functionality on page 14. The 500G ERT module supports local data auditing of installation programming. Local auditing features the listed characteristics.
500G ERT® Module Installation Guide, Remote Mount Chapter 2 About the OpenWay Riva Remote 500G ERT Module As a component of the Itron Openway Riva solution, the 500G ERT module supports the security model found in the OpenWay solution for both reading and programming. If the ERT modules are shipped without security enabled (ready to secure), the utility can—at a later date—configure the modules for ISM enhanced security.
500G ERT® Module Installation Guide, Remote Mount Chapter 2 About the OpenWay Riva Remote 500G ERT Module Functional specification Description Australia ACMA AS/NZS 4268 Frequency: 915 to 928 MHz ISM band Program frequency: 916 to 926.
500G ERT® Module Installation Guide, Remote Mount Chapter 2 About the OpenWay Riva Remote 500G ERT Module Firmware part Global soft- FDM Check Over-the-air number ware release Endpoint firm- firmware part (GSR) version ware version number 4.5 2.2.6 N/A Direct Mount: FMW-7002-012 Firmware Functionality ■ GSR 4.
500G ERT® Module Installation Guide, Remote Mount Chapter 2 About the OpenWay Riva Remote 500G ERT Module Document title Document part number OpenWay Riva 500G Gas ERT Module Specification Sheet 101510SP-0X Field Deployment Manager Tools Application Guide TDC-1713-XXX Field Deployment Manager Tools Configuration Guide TDC-1711-XXX Field Deployment Manager Field Representative's Guide TDC-1714-XXX Note: The last three digits of the user and installation guides represent the document's revision le
3 Mounting This chapter provides the instructions to mount the remote 500G ERT module on a pipe or other flat vertical surface (wall). Standard Installation Options Mount the remote ERT module using the pipe mount or wall mount (flat vertical surface) procedure. ■ Pipe mount. Itron offers a pipe installation kit (CFG-0005-003) to mount the remote ERT module on a pipe. ■ Flat vertical (wall) mount. Installation using the wall mount option places the module on a wall or other vertical surface.
500G ERT® Module Installation Guide, Remote Mount Itron part number CFG-0005-003 Chapter 3 Mounting the Remote 500G ERT Module Description Pipe mount kit contents: ■ 2 band clamps ■ 2 tamper seals ■ 1 pipe bracket ■ 2 cable ties ■ 1 adapter plate ■ the following screws: 1. SCR-0215-001 (2) #8-16 x ½ inch slotted panhead tapping screw, corrosion-resistant steel. Attaches the adapter plate to the pipe bracket. 2. SCR-0215-002 (2) #8-16 1-inch slotted pan-head tapping screw, corrosion-resistant steel.
500G ERT® Module Installation Guide, Remote Mount Chapter 3 Mounting the Remote 500G ERT Module 3. Push the end of the clamp's band through the holes in the pipe bracket as shown. 4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. a. Push the end of the band through the band clamp screw assembly. b. Turn the band clamp's screw assembly to fit into the pipe bracket opening. c. Tighten the clamp screw until the band clamp is secure on the pipe. 5.
500G ERT® Module Installation Guide, Remote Mount Chapter 3 Mounting the Remote 500G ERT Module 9. Align the ERT module back-plate mounting holes with the pipe mount adapter plate holes. Install the two one-inch ERT module mounting screws from the installation kit. Tighten the module mounting screws evenly in an alternating pattern. Tighten the screws to 9 to 12 inch-pounds torque. 10. Insert the tamper seals. 11.
500G ERT® Module Installation Guide, Remote Mount Chapter 3 Mounting the Remote 500G ERT Module Selecting and Installing On a Wall or Flat Vertical Mounting Location Carefully select a mounting location free from electrical wires. The mounting location must have the proper clearance to accommodate the 1-1/2-inch module mounting screws so nothing is damaged by the drill or mounting screws. Use a compatible mounting screw. 1. Drill three pilot holes in the mounting surface.
4 Programming Caution: You must program the 500G ERT module before use. Programming Itron ERT modules requires an understanding of: ■ Your meter's drive rate and the number of dials ■ ■ The drive rate and number of dials is important for programming the module to count correctly and roll over to zero at the correct time. For example, a four-dial, 2 cubic-feet meter configuration will count two cubic-feet for each rotation and roll over to zero after 9999.
500G ERT® Module Installation Guide, Remote Mount Chapter 4 OpenWay Riva Remote 500G ERT Module Programming ■ RF at capacity (2,000 maximum per cell) ■ Average of one two-way command/response per week Programming the Remote 500G ERT Module Program the meter drive rate into the remote ERT module using a compatible programming device. 1.
500G ERT® Module Installation Guide, Remote Mount 25 July 2019 Chapter 4 OpenWay Riva Remote 500G ERT Module Programming TDC-1678-005 24
500G ERT® Module Installation Guide, Remote Mount Chapter 4 OpenWay Riva Remote 500G ERT Module Programming Programming example Endpoint programmed for 6 dial, 1000 cubic feet CCF. 1. Enter the initial index read. For this example, the initial read is 123456 where 6 = 600 cubic feet. After the initial programming, an endpoint read will result in a reading of 1234560 where the least significant digit is in 10's of cubic feet.
500G ERT® Module Installation Guide, Remote Mount Chapter 4 OpenWay Riva Remote 500G ERT Module Programming Field Collection System (FCS) (Mobile Mode only) In FCS, a Read Type Code can be assigned to a meter session. The Read Type Code in conjunction with the Endpoint Type is used to determine how the endpoint reading is formatted using the Endpoint Translation table in FCS.
5 Specific Meter Manufacturer Installation This chapter provides the instructions to install the 500G remote ERT module to compatible meters. Reference each section for compatible meters. Eagle Research Meter Installation This section provides the information to install the 500G remote ERT module on the following compatible Eagle Research correctors.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Programming requires a computer loaded with the Eagle Research Software and an Eagle Research computer-to-volume corrector communication cable. 2. Connecting the ERT module to the volume corrector. Requires a wire stripper and flat-tip screwdriver sized to tighten the terminal connections on the Eagle corrector. 3. Mounting the remote ERT module.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 2. Insert tamper seals into the tamper seal mounting cups on the remote ERT modules. 3. With the corrector facing forward, align the corrector mounting holes with the index drive mounting holes. 4. Insert the corrector's mounting screws in the front corrector and index mounting holes. Loosely tighten the front two mounting screws. 5.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation For uncorrected reads: 5. Connect: ■ the twisted blue and white wires to terminal 17 on the MPplus terminal block. ■ the red remote ERT module wire to terminal 18 on the MPplus terminal block. For corrected reads: 6. Connect the twisted blue and white wires to terminal 15 on the MPplus terminal block. 7. Connect the red remote ERT module wire to terminal 16 on the MPplus terminal block. 8.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 2. Pull the lead wires through the compression connector until there is adequate wire to reach the K2 terminal port. 3. Tighten the compression connector. 4. Connect the red remote ERT module wire to pin 4 of the K2 terminal port. 5. Twist the remote ERT module's blue and white wires together and connect the twisted blue and white wires to pin 5 of the K2 terminal port. 6.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 11. Connect the red remote ERT module wire to pin 1 on the K1 terminal port. 12. Twist the remote ERT module's blue and white wires together. 13. Connect the twisted blue and white wires to terminal 2 on the K1 terminal port. Eagle Research Corrector Programming and Requirements Notes Important! This information is subject to change without notice.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation A Connect to Remote window opens. 4. Select the following parameters: ■ Connection Type: Direct ■ Communications Port: enter your computer's port number ■ Baud Rate: enter the baud rate that displayed in Step. 2. 5. Click OK. 6. Click View/Config. The Field Manager window opens and displays the settings for the current connection. 7. Click the Setup Parameters tab at the bottom of the parameters window.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 9. Enter the parameters shown in the Corrected Pulse Output Setup section in the lower left of the window. 10. Click Send All Changes. 11. Verify that all parameters are correct. 12. Click Disconnect. Using Eagle Research Field Manager to Change the XARTU Corrector Settings 1. Open the Eagle Research Field Manager from the Start menu or the desktop shortcut. 2.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 5. Click View/Config. Click OK 6. Click the Setup Parameters tab at the bottom of the parameters window. The Meter Setup and Accumulation Multipliers window opens. Set up the meter and accumulation multipliers as appropriate for your installation. 7. Enable K2 (4, 5, 6) and set additional parameters are required in the Uncorrected Pulse Output Setup section in the lower right of the window. 8.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation the module drive rate settings match those set in the corrector. For example, set the ERT module drive rate for 1000 CF when the Eagle Research corrector drive rate is set for 1000 CF. Elster American meter installation Some meter manufacturers provide ERT mounting kits and installation procedures for their meters.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 500G module configuration with the meter is dependent on your system application. See the Elster American meter configuration information. Elster American Meter Mounting Instructions 1. Remove the meter's top plate by removing the two 5mm screws and carefully prying up on the plate. The plate is secured with an O-ring seal. Remove the O-ring from the plate.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 5. If you removed the register cover, replace the cover using the four (4) 5mm mounting screws. 6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4-pin female connector inside the meter's tower. The connectors will slide together and latch. 7. Carefully push the connectors and wires into the meter tower housing. 8.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 1. Trim the remote module wires to 3.5 inches. 2. Carefully strip the insulation covering from the meter cable (purchased from the meter manufacturer) approximately 1-1/2-inches from the end. Caution: Do not cut through the individual wire insulation. 3. Separate the meter cable's black, white, and red wires for connection to the remote module.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 5. Insert the meter cable through the slot on the remote module backplate. Install a cable tie to the meter cable wire below the meter cable insulation to provide strain relief. 6. Tuck the connectors and cable tie into the remote module housing. Place backplate on the assembly and tighten the four backplate screws using a size T-10 Torx screwdriver.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Galvanic Gas Micro Installation This section describes installation to Galvanic compatible correctors. Meter model Meter notes Module type Must select 2 pulses/second from pulse output on the output frequency menu.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Galvanic Mechanical and Wiring Installation Instructions GAS Micro wiring connections GAS Micro corrector P13 connection 100G ERT module wires Pulse output1-C C1 Blue/white Pulse output1-E C2 Red Pulse output2-E C3 Pulse output2-C C4 Programming the Galvanic Gas Micro Electronic Volume Corrector For more information about programming the Galvanic Gas Micro Electronic volume corrector, see the
500G ERT® Module Installation Guide, Remote Mount Meter model B3 Series pulse output meter LMMA pulse output meter Integral Micro Corrector IMC/W2 Chapter 5 Specific Meter Manufacturer Installation Meter notes Module type Itron part ERT mod- number ule notes Rotary meters 500G remote equipped with WeighandWire solid state pulsers. Meter must have factory-installed pulser with connector output. Purchase correct cable interface from GE Dresser. Pulser must be version 17 or higher.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation GE Oil and Gas 500G Installation Overview Installing the 500G remote ERT module to a GE Dresser meter involves the following tasks. 1. Programming or verifying that the meter is set up to work with the 500G remote ERT module. ■ Programming may require a computer and communication cable. 2. Wiring the GE-supplied cable to the ERT module or wiring the ERT module to the GE device.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation GE Oil and Gas ES3 or ETC Ordered with the AMR-ready Mounting Kit 1. Score (cut) the cable jacket surrounding the ES3 or ETC wires and carefully remove the cable jacket to expose the ES3 or ETC wires. 2. Connect the wires to the ERT module. For more information, see GE Oil and Gas Meters With Pulse Output Wiring on page 51. 3. Align the ERT module mounting holes with the ES3 or ETC bracket mounting holes.
500G ERT® Module Installation Guide, Remote Mount Quantity Chapter 5 Specific Meter Manufacturer Installation Description GE Dresser part number Important: The GE Oil and Gas mounting bracket kit does not include the cable required to connect the remote module to the Amphenal connector on the IMC\W2. Completing the Bracket Installation 1. Insert the 8-32 x 7/16-inch screw (1) into the top of the mounting bracket. Insert the two 8-32 x 3/4-inch screws (2) into the bottom of the mounting bracket. 2.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Caution: Upright vertical positioning is very important because the remote module is: ■ designed with the antenna in a vertical direction so the antenna is parallel to the reading device (which has a vertical antenna). Matching antenna polarity can greatly affect RF performance and enable easy ERT module reading. ■ designed so the tilt tamper is vertical.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation D800/D1000 Wiring and Installation 1. Loosen and remove the two screws holding the mounting brackets to the meter. 2. After the brackets are removed, the pulse output cable is visible. 3. Loosen the cable gland and pull the cable out until it extends 7.5 to 8" out of the cable gland. 4. Tighten the cable gland. Do not use a pliers or wrench to tighten the cable gland. 5. Rotate one bracket.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 6. Attach the brackets to the meter using the previously removed screws. 7. Splice the meter pulse output wires to the ERT module wires using gel cap connectors. Follow the wire connections for the D800/D1000 to 500G ERT module wire connections below. Note: Use a crimping tool compatible with gel-connectors.
0G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 10. Carefully fold the ERT module wires into the module's housing. Do not pinch the wires of gel connections between the housing and the backplate. 11. Install the four back plate screws using the T15 Torx screws supplied with the ERT module. 12. Route the cable through the channel in the backplate standoffs. 13.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 16. Install the supplied red tamper seals over the bottom mounting screws on the remote ERT module. GE Oil and Gas Meters With Pulse Output Wiring These instructions describe B3 series, LMMA series, IMC, IMC/W2, MC2, and Series ES3 and ETC wiring connections. Installations are similar in their wiring of a meter manufacturer cable to the ERT module that is then connected to the index or instrument.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation GE supplied cable that connects to a B3, LMMA, IMC/W2, or MC2 ERT module White White Red Red Pulse output Wire ES3 or ETC Pulse output 1 only Pulse output with 1 fault ERT module Output 1+ White White and blue White Output 1- Black Red Red Output 3+ Red White Output 3- Green Blue Wiring for direct connection to the IMC/W2 To receive uncorrected reads: Connect the red wire to termi
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Wiring for direct connection to the IMC/W2 4. Tuck the three gel connectors and cable tie inside the module housing, as shown in the placement illustration and schematic. 5. Install the 500G ERT remote module backplate using the four screws previously removed from the module and a Torx T-10 screwdriver. 6. Plug the cable into the pulse output of the index.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 5. Select the Configuration tab to view the volume configuration or confirm the volume configuration and pulse settings. Use the drop-down lists to change the variable's setting. Note: You must click OK to complete any setting changes. Testing IMC or W2 communication with GE User Terminal (UT) communication software 1. Connect the IMC/W2 to the PC using the serial cable. 2.
500G ERT® Module Installation Guide, Remote Mount Meter model Chapter 5 Specific Meter Manufacturer Installation Meter notes Module Itron type part ERT module notes number Mini-AT Mini-Max Pressure and temperature electronic volume instruments. Instruments must have a Form A board. Form C is NOT supported. Item #56 Pulse Scaling Factor must be 2.0. Item #96 Cor Vol Display must be 7, 6, 5, or 4 digits (1, 2, 3, or 4 blanks). Item #115 Output Pulse Code must be set at 1, 2, or 4.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Honeywell Instrument installation overview Installing the 500G remote ERT module to a Honeywell Instrument involves the following tasks. 1. Programming the instrument and verifying that the Honeywell instrument is set up to work with the 500G remote ERT module. Programming requires Honeywell software. Reference Honeywell product and software documentation for the correct software and version requirements.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 4. Remove the two hex screws from the input switchboard and the switchboard from the enclosure and set it aside. You will re-install the switchboard later. Warning: The battery pack, main board, and switchboard may be damaged if left in the Honeywell Instrument volume corrector while completing this installation. 5.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 11. Insert the module cables (both units) through the large cable strain relief on the left rear of the instrument's enclosure. Leave a one-half to one inch drip loop under the cable strain relief. 12. Secure three cable ties on the module cables in three places on the cables as specified by information included in the kit. 13.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 3. Strip one inch of the outer insulation from the cable. Warning: Keep wires away from the rotating magnetic spindle in the Honeywell Instrument. 4. Strip ¼-inch individual wire insulation from the red, white, and blue lead wires. a. Count enabling wire (pulsed ground reference) b. Count sensing wire (high impedance positive reference) c. Cut cable sensing wire (positive return) 5.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 6. Connect the red wire following the Item Code Settings. For Item Code Settings, seeProgramming the Honeywell Instrument Parameters on page 64. Note: In Honeywell Instrument EC-AT correctors, the connector may be soldered to the pulse board.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Form-A pulse outputs are configurable for compensated or uncompensated volume. The FormB output is for alarm output use only. Connections to the three output pulse channels are completed using loose unterminated wires (the individual wires from a cable) and gel-connectors.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 4. Place the strain relief fitting onto the field pulse cable. 5. If the field pulse cable is smaller than a 0.2-inch diameter, install the rubber tube supplied with the TCI onto the cable so the strain relief will clamp onto the tube after it is reinstalled. 6. Connect the individual external pulse cable conductors to the unterminated wires following Configuration for two ERT modules connected to one TCI.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 10. Insert the gel-connected wires into the threaded gray adapter plate hole. 11. Replace the strain relief and tighten until secure. Honeywell Instrument Programming and Requirements The Honeywell MasterLink SQL software is used to configure Honeywell products. Important! This information is subject to change without notice.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 5. To view an Item configuration, select Display > Items by Number. 6. Verify that the Honeywell instrument settings are correct. For example, Item number 56 must be set to 2.0. If the setting is incorrect, click the Change button. A Change Item pop-up provides the interface to change the setting. 7. Enter the correct setting. Click Save. 8.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Channel A Channel B Corrected Uncorrected Volume Channel C Pulse Output Spacing #58 #115 Volume Instrunment- Pulse #56 #93 #57 #94 #95 #1014 #1015 Terminal Output Board Con- Options nections / Wiring Wiring Ver-2(3) Blue and White ERT wires go to Y or Form A 2=2.0sec Pulse board Ver3(2) 2 Cor or Vol 4=0.
500G ERT® Module Installation Guide, Remote Mount Meter model Chapter 5 Specific Meter Manufacturer Installation Meter notes Itron part num- Module notes ber 1A Flat-face meter body and 1A adapter plate have interference fit issue causing direct-mount solution to be non-compatible. 305 #2 flat-face meter ERG-7000-501 #3 flat-face meter 400 Front-mount index ERG-7000-501 Requires a thicker gasket for magnet hub to clear index box.
500G ERT® Module Installation Guide, Remote Mount Meter model Chapter 5 Specific Meter Manufacturer Installation Meter notes Where direct mount solution is not compatible Module type 500G Itron part ERT mod- number ule notes ERG7000-501 All meters Romet Meter Installation This section describes installation for Romet meters and correctors compatible with Itron 500G remote ERT modules.
500G ERT® Module Installation Guide, Remote Mount Meter model Chapter 5 Specific Meter Manufacturer Installation Meter notes Module Itron type part ERT module notes number Meter must have factory-installed pulser with connector output. Purchase cable interface from manufacturer. 500G remote ERG7000-503 RM Series STD CTR 600-5600 TC 2000-23000 Meter must have connector pin with factory-installed pulse output. Purchase correct cable interface from Romet.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation ■ RometLink communication software, available from Romet ■ 3 gel cap connectors, Itron part number CON-0023-001 ■ 3M crimping tool ■ Torx T-10 screwdriver ■ Remote ERT module with backplate and four included Torx screws (included with module) 3. Mounting the remote ERT module (for more information, see Mounting on page 17). Select the mounting option appropriate for your installation.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Romet ECM2® to remote ERT module mounting option 2. Insert the mounting screw fitted with the three lock washers. Two lock washers are used as spacers (as shown). 3. Attach the mounting plate to the meter. Insert the mounting screw where the module screw was removed. Torque the mounting screw to 5-7 ft.lbs. to secure the plate to the Romet meter. 4.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation configurations. For specialized setup instructions, contact Romet. 1. Remove the ERT module backplate (4 screws) to expose the module lead wires. The backplate and screws will be re-installed on the ERT module later in this procedure so store them (temporarily) in a safe, secure place. 2.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Romet ECM2® meter wiring The Romet ECM2® meter The meter has three Form "A" outputs that can be configured at the factory to provide any combination of the following three outputs: ■ Uncorrected volume (UNC VOL) ■ Corrected volume (COR VOL) ■ Alarm The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items > SET UNC OUT and Menu items > SET COR OUT.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Romet cable number 34-125-42 Cable pin ERT module wire Corrected A White and blue B Red Uncorrected Alarm C White and blue D Red E White and blue F Red Romet cable number 34-125-43 Cable pin ERT module wire Corrected A White and blue B Red Aux CC C White and blue D Red Alarm E White and blue F Red Romet cable number 34-125-44 Cable pin ERT module wire Aux CC A B C White a
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Romet cable number 34-125-45 Cable pin ERT module wire Corrected Uncorrected A White and blue B Red C Alarm White and blue D Red E White and blue F Red Romet cable number 34-125-50 Cable pin ERT module wire Corrected Uncorrected 1 Alarm Red 2 White and blue 3 White and blue 4 Red 5 Red 6 White and blue Romet cable number 34-125-51 Cable pin ERT module wire Correct 1 2 Unc
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 4. After the wire connections are completed, install a cable tie to the meter cable just below the exposed colored lead wires on the cable insulation. 5. Remove the excess cable tie using a hand-held side-cutter pliers. The cable tie performs as a cable strain relief to mitigate the risk of destructive tension on the lead wires. 6.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Romet Corrector Programming and Requirements Notes AdEM programming Note: Meter setup requires confirmation of communication settings with the AdEM corrector. Communication confirmation requires the RometLink software and the Romet communication cable. 1. Install the RometLink software on your PC. 2. Connect the AdEM corrector communication cable to your computer and the AdEM corrector. 3.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 3f. From the Talk to Unit tab, select Setup > Default. 3g. Set the following Default Setup Group parameters: ■ Enter the desired Cor. Volume Unit parameter. Set Cor. Pulse Volume to the same number of units. ■ For Output Pulse Spacing, enter the largest number over 285mS that works for your application. Itron recommends a setting of 350mS.
500G ERT® Module Installation Guide, Remote Mount Meter model Chapter 5 Specific Meter Manufacturer Installation Meter notes Itron part num- Module notes ber Sonix meters are pulse output registers which are programmed by Sensus software. Proper pulse output options and display options must be selected. ERG-7000-503 Sonix pulse output 12, 16, 25, 57 (Metric) 600, 880, 2000 (cubic foot) Sensus meter installation overview Installing the remote module to a Sensus meter involves tasks: 1.
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation 1 Top anchor screw positions 2 Bottom anchor position for the module U-shaped mount Order the correct Sensus Sonix direct mount bracket for your installation requirements from Sensus North American Gas Customer Service. (Brackets and mounting hardware are ordered separately).
500G ERT® Module Installation Guide, Remote Mount Chapter 5 Specific Meter Manufacturer Installation Sensus Meter Mechanical and Wiring Installation Instructions Sensus Sonix meters provide a standard Form A electronic pulse output compatible with the remote module. You may connect the Sensus Sonix meter to the remote module using the pulse output cable or you can directly mount the remote 500G ERT module to the meter.
6 Diaphragm Meter Installation This chapter provides the instructions to install remote modules (Itron part number ERG-7000501 with 2.5-foot cable and encoder) on diaphragm gas meters where a direct mount 500G ERT module is not possible.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation The following materials are required for each remote module installation to a diaphragm gas meter. Purchase these items from Itron. Part Number Description ERG-7000-501 Remote 500G ERT module with 2.5' encoder cable CFG-0081-001 Remote mount encoder kit 1. acetone applicator stick 2. tamper seals 3. cable ties 4. mounting screws 5. magnet hub spacer 6. magnet hub 013-1723-112 Encoder spacing tool.
500G ERT® Module Installation Guide, Remote Mount 4-hole front cover gasket: Itron part number FAB-0014003 Chapter 6 Diaphragm Meter Installation 2-hole front cover gasket: Itron part number FAB-0014002 1-hole front cover gasket: Itron part number FAB-0014001 The Itron replacement index cover gaskets shown below are thicker than standard gaskets and have a special slot to accommodate the encoder cable. Gaskets are designed for Schlumberger/Sprague model 675 and 1000 commercial diaphragm meters.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation 1. Remove the diaphragm meter index cover and index. Use care to hold the index cover and index while loosening the screws to protect them from damage if they are dropped. a. Remove the index cover screws in an alternating pattern. Hold the index cover while the screws are removed to protect it from damage due to being dropped. b. Remove the index cover and set aside. c.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation 4. Briefly place the magnet side of the magnet hub into the curved indentation in the encoder as shown in the illustration. Remove the magnet hub from the encoder and set it at least one inch away from the encoder. 5. Use an ERT module programming device to read the remote module. If this reading is higher than the reading taken after the index was removed, the remote is counting and working properly.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation 8. Press the magnet hub down over the hub spacer as far as possible. The bottom of the hub spacer may touch the index face. Turn the dial after magnet hub installation to verify that the index dial functions with a smooth, easy rotation. 9. If the dial needle tip sticks out past the edge of the magnet hub, cut off the end of the dial needle as close as possible to the magnet hub with sharp, side-cutting pliers. 10.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation 13. Peel the protective plastic away from the adhesive side of the encoder. Important: You must do the next two steps exactly as described or the remote ERT module will not work properly. 14. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown below, with the adhesive side down.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation 17. Use the correct replacement gasket for your meter's index. Remove the gasket center and index cover-hole plugs from the new gasket. Insert the index and encoder assembly through the gasket center with the gasket's adhesive-backed side facing the meter. 18. Align the index wriggler with the meter's drive dog. Install the index on the meter using the index mounting screws. Tighten one index screw two turns.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation Caution: Route the encoder cable inside the index cover to provide strain relief (minimize pulling or twisting on the encoder). Verify that the strain-relief cable tie on the encoder cable is inside the index cover when the cover is installed on the meter. The gasket must align with the index cover screw holes and adhere to the meter face to ensure a proper seal after the index cover is installed. 21.
500G ERT® Module Installation Guide, Remote Mount Chapter 6 Diaphragm Meter Installation Commercial Module Programming Notes Take note of the index drive rate shown on the index. The ERT is programmed based on the drive rate. Elster American commercial meter index drive rates may be 5-, 10- or 100 cubic feet. The index shown has a 10-cubic foot drive rate.
7 Optional Sealant Application Instructions In areas where insect intrusion is a problem, Itron recommends an optional sealant to help keep insects out of the ERT module housing. The Itron-tested and approved sealant (Itron part number ADH-5106-000) is used to seal gaps in remote ERT module installations that can allow insect intrusion. 1. Prepare the module for the sealant by verifying the application area is clean and dry. Warning: Apply sealant in a well-ventilated area.
500G ERT® Module Installation Guide, Remote Mount Chapter 7 Optional sealant application instructions 2. Itron recommends sealant application after the remote module is installed so the cable is in the installation position. Use the sealant (ADH-5106-000) to fill the gap. 3. Use enough sealant to fill the gap. Wipe off any excess sealant and replace the cover on the sealant tube.
8 Using Gel-cap Connectors to Complete Wiring Connections This section provides the instructions to complete remote ERT module to meter wiring connections. Gel-cap connections require: ■ E-9R 3M® gel-cap crimping tool ■ 3M gel-cap connectors (Itron part number CON-0023-001) 1. Push the two wires into the connector as far as possible. Caution: Do not strip insulation from the ends of the wires before inserting them into the connector. 2.
500G ERT® Module Installation Guide, Remote Mount Chapter 8 Using gel-cap connectors to complete wiring connections 4. The connector is properly crimped when the top of the moveable yellow center (1) is flush with the top of the connector body (2). Warning: Crimping the connector forces sealant out of the connector. The sealant protects the inside of the connector against insects, moisture, or other contaminants. The sealant may cause minor eye and skin irritation. Avoid eye contact.