4. Beginning over the installed electrical tape, twist the Itron cable armor onto the Cellular
500W remote module cable using a right-handed twist.
Warning! You must twist—not wrap—the cable armor onto the Cellular 500W
remote module cable. Wrapping the cable armor can cause the stainless steel
jacket to warp.
You must begin twisting the cable armor over portion of the cable protected by the
electrical tape. If you do twist the cable armor onto the Cellular 500W remote
module cable on the unprotected portion of the Cellular 500W remote module
cable, you could damage the module's cable. A cut cable could cause an Cellular
500W remote module or register communication failure.
5. Continue to twist the cable armor onto the Cellular 500W remote module cable until the
cable armor covers the entire cable.
6. Remove any leftover materials from the customer premises. Discard or recycle leftover
materials.
Cellular 500W Module Remote Installation Guide 6 Using the Itron Cable Armor