Caution: Install the wires around the screws in a clockwise direction (as shown)
or the wires may come out from under the screw heads as you tighten them. Also,
verify that insulation is NOT compressed under the screw head, or the wire may
not make good contact.
7. Install the module and mounting bracket on the meter register adapter collar.
8. Replace the hollow pin (1) you removed in step 1.
Direct-mounting to a Badger Direct-Mount Register
Note: Verify you have a Badger meter with a register designed for direct mount OpenWay
Riva remote modules. Check the part number on the label to verify the module matches the
meter. Always install the module with the arrow on the housing pointing upward. The register
may or may not be mounted on the meter when performing the following steps.
Cellular 500W Module Remote Installation Guide 4 Installing the Cellular 500W Remote Module
10 March 2021 815-0618-00 REV 000 Itron, Inc. Page 33 of 43