1. Push the hollow pin (1) completely out of its location and separate the Cellular 500W remote
module mounting bracket (2) from the meter register collar (3).
2. Strip 1/2-inch of insulation from the end of the brown, gray, and yellow wires.
3. Place the Cellular 500W remote module on the mounting bracket and route the yellow, gray,
and brown wires through the opening.
Note: A gasket is not required.
4. Install four Torx-head mounting screws (Itron part number SCR-0010-005).
5. Hand-tighten each screw.
6. Connect the Cellular 500W remote module wires to the register screw terminals following
the Cellular 500W remote module to the Elster/AMCO meter register wire connections. After
the wires are connected, carefully tuck the connectors into the Cellular 500W remote module
housing. Tighten all screws securely.
Cellular 500W Module Remote Installation Guide 4 Installing the Cellular 500W Remote Module
10 March 2021 815-0618-00 REV 000 Itron, Inc. Page 32 of 43