Caution: The FC300SR or Itron Mobile Radio are the only devices that support
programming for the remote module endpoint.
The remote module and programmer should be a minimum of 12-inches apart while
programming.
Do not place the programmer antenna directly on the remote module.
Encoder-type Register Connections
Connect the wires from the Cellular 500W Cellular 500W remote module to the register screw
terminals according to the following table.
Note: Itron recommends 19-26 gauge, pre-bonded or solid conductor wire with a maximum
diameter of .082" (individual wire insulation). The use of un-bonded wire may produce an
unreliable connection when using gel caps for joining wires.
Cellular 500W remote module wire color
Brown (data) Gray (power/clock) Yellow (ground)
Register manufacturer Register screw color designator
■ Badger
■ ADE
■ E Series
■ HR E LCD
■ HR E Mechanical
Green Red Black
Badger M5000 Mag Meter Green terminal: Out
4+
Red terminal: Input + Black Input - and Out
4 -
■ Elster AMCO
■ Invision
■ Scancoder
■ AquaMaster
■ AquaMaster III
Red Green Black
Diehl Hydrus Green White Brown
■ Elster AMCO
■ SM 700 (Severn Trent)
■ Q200 (Sensus protocol)
■ evoQ4 (Sensus Protocol)
Green Red Black
Cellular 500W Module Remote Installation Guide 3 Initializing and Connecting