Installation Guide

Caution: Any pit module position other than upright will negatively affect radio
performance.
9. Screw the bottom screw into the pilot hole until snug. Do not over-tighten the mounting
screw.
Wall mounting the OpenWay Riva pit module is complete.
Leak Sensor (OLS) Installation
Installation of the OLS with a pit Cellular 500W module requires the OLS with an inline connector
(Itron part number LDS-1601-001). The OLS connects to the telemetry connector on the pit
module. For pit module installation instructions, see the installation guide for your Cellular 500W
module.
If the OLS 5 foot cable is not long enough to reach the OpenWay Riva Pit Cellular 500W Module,
an extension cable is available from Itron (CFG-0151-404). The maximum cable length between
the OpenWay Riva Leak Sensor and the OpenWay Riva Pit Cellular 500W Module is 30 feet.
Caution: If the pit module is installed to enable communications for the OLS but a
register is not connected, replace the register connector's cap (2) with the
environmental cap removed from the blue telemetry connector (1) to protect the
register connector.
Cellular 500W Module Pit Installation Guide 3 Installing the Cellular 500W Pit Module
09 March 2021 815-0617-00 REV000 Itron, Inc. Page 22 of 41