- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Using Gel-cap Connectors to Complete Wiring Connections
- 8 Optional Sealant Application Instructions
20. Remove the protective backing on the replacement gasket to
expose the adhesive side of the gasket. Align the gasket (1),
encoder cable (2), and cable tie (for strain-relief) (3) on the meter
as shown.
Caution: Route the encoder cable inside the index cover to provide strain relief (minimize
pulling or twisting on the encoder). Verify that the strain-relief cable tie on the encoder cable
is inside the index cover when the cover is installed on the meter. The gasket must align
with the index cover screw holes and adhere to the meter face to ensure a proper seal after
the index cover is installed.
21. Install the four index cover screws and tighten just enough to
hold the screws in place.
22. Verify that the encoder cable is in the correct position in the
cable slot of the gasket. Fully tighten the screws in an alternating
pattern. Install utility-approved security seals and wires as
required.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation