15. Remove the encoder spacing tool and lay the index on a flat,
horizontal surface to reduce strain on the encoder cable.
16. Program the index reading (with the encoder mounted) into the remote module. Read the remote module and verify
that the reading matches the read programmed into the remote module.
17. Use the correct replacement gasket for your meter's index.
Remove the gasket center and index cover-hole plugs from the
new gasket. Insert the index and encoder assembly through the
gasket center with the gasket's adhesive-backed side facing the
meter.
18. Align the index wriggler with the meter's drive dog. Install the
index on the meter using the index mounting screws. Tighten one
index screw two turns. Install and tighten the remaining index
screw. Tighten the first index mounting screw completely
(alternating fashion).
19. Install a strain-relief cable tie about 1-1/4-inch from the encoder cable's stripped end. The cable tie must be inside the
index cover after the cover is installed on the meter. Remove any excess cable tie with a side-cutting pliers and dispose
the excess cable tie.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation