11. Tilt the acetone stick vertically with the applicator foam end down. Squeeze the acetone stick on the black dot until the
packet inside the pen breaks. Continue to hold the pen in a vertical position until the acetone wicks into the foam
applicator end. Apply a thorough coat of acetone to the index where the encoder will be installed. Do not touch the area
where the acetone was applied before the encoder is installed.
12. Slide the thin end of the encoder spacing tool down over the magnet hub.
13. Peel the protective plastic away from the adhesive side of the
encoder.
Important! You must do the next two steps exactly as described or the remote module will
not work properly.
14. Press the curved side of the encoder firmly against the side of the encoder spacing tool as shown below, with the
adhesive side down. Slide the encoder down along the side of the encoder spacing tool until it touches the surface of the
index (as shown below). Using moderate pressure, hold the encoder firmly against the index, without moving, for 15
seconds to permanently apply the encoder.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation