7. Align the pointer (1) on the top of the magnet hub and the notch
(2) in the side of the magnet hub with the needle (3) of the meter
drive rate dial.
8. Press the magnet hub down over the hub spacer as far as
possible. The bottom of the hub spacer may touch the index face.
Turn the dial after magnet hub installation to verify that the index
dial functions with a smooth, easy rotation.
9. If the dial needle tip sticks out past the edge of the magnet hub,
cut off the end of the dial needle as close as possible to the
magnet hub with sharp, side-cutting pliers.
10. Remove the acetone stick applicator from the remote encoder installation kit (Itron part number CFG-0081-001).
Select a location on the index face next to the magnet hub for the encoder installation. After installation, the encoder cable
must not interfere with the index dials.
Note: If a TEMP COMP sticker is attached to the index where the encoder cable will mount,
remove it before cleaning with the acetone stick. If the sticker (or replacement sticker) must be put
back on the register face, place it in a new location on the index face after the encoder is attached.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation