Module Mounting
For remote module mounting with the diaphragm meter, see Mounting on page 16.
Diaphragm Meter Mechanical and Wiring Installation
Instructions
Caution: The remote module encoder must be installed at temperatures between
40° and 95°F to ensure proper adhesion.
1. Remove the diaphragm meter index cover and index. Use care to hold the index cover and index while loosening the
screws to protect them from damage if they are dropped.
a. Remove the index cover screws in an alternating pattern. Hold the index cover while the screws are removed to
protect it from damage due to being dropped.
b. Remove the index cover and set aside.
c. Remove the screws holding the index to the meter. Hold the index to protect it from damage due to being dropped.
d. Set the index aside.
2. Remove the old gasket and any gasket residue from the meter
and index cover.
3. Remove the magnet hub from the encoder installation kit (Itron part number CFG-0081-001). Verify that there is only
one magnet in the hub.
Note: If there is no magnet or if there are two magnets in the magnet hub, discard the hub. Encoder
installation requires a magnet hub with one magnet.
Cellular 500G Module Remote Installation Guide 6 Diaphragm Meter Installation