Sensus Meter Mechanical and Wiring Installation Instructions
Sensus Sonix meters provide a standard Form A electronic pulse output compatible with the
remote module. You may connect the Sensus Sonix meter to the remote module using the pulse
output cable or you can directly mount the remote module to the meter.
Sensus meter wiring
Sensus Sonix 2000 meter pulse output options
Option (1) Pulse 1 (+) (2) Pulse 2 (+)
(3) Ground (-)
1 Uncorrected Corrected
2 LCD index volume Alarm
Sensus Sonix 600 or 880 meter wiring
Meter wire module wire
Red White and blue
Black Red
For more information about programming wiring parameters, contact Sensus North American
Gas Customer Service.
Sensus Meter Programming and Requirements Notes
Using the SonixCom software, configure the Sensus Sonix meter parameters with the following
the Sensus pulse output settings.
■
1 pulse per 10 cf
■
1 pulse per 100 cf
■
1 pulse per 1000 cf
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation