Cable
pin
module wire
Correct Uncorrected Aux CC
3 White and blue
4 Red
5 Red
6 White and
blue
4. After the wire connections are completed, install a cable tie to the meter cable just below the
exposed colored lead wires on the cable insulation.
5. Remove the excess cable tie using a hand-held
side-cutter pliers. The cable tie performs as a
cable strain relief to mitigate the risk of destructive
tension on the lead wires.
6. Tuck the three gel connectors and cable tie inside the module housing, as shown in the following
placement illustration and schematic.
7. Install the remote module backplate using the four screws previously removed from the module and a Torx
T-10 screwdriver.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation