Installation Guide

Table Of Contents
Connection Corrected count
Romet cable module
Cut Cable Alarm Green Blue
Note: The pigtail cable is the cable extruding from the back of the AdEM corrector.
You must select the pigtail cable at the time the AdEM corrector is ordered.
Romet ECM2 Meter Wiring
The Romet ECM2 meter
The meter has three Form "A" outputs that can be configured at the factory to provide any combination of the
following three outputs:
Uncorrected volume (UNC VOL)
Corrected volume (COR VOL)
Alarm
The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu items > SET UNC OUT
and Menu items > SET COR OUT. Since Setup Mode is fully configurable, the ECM2 module is universally
adaptable to all Romet TC meter bodies. Reference the Romet technical manual for specific details on the
ECM2.
Romet Cable Number 34-125-20
Cable pin module wire
Corrected Uncorrected Alarm
A White and blue
B Red Red
C White and blue
D Red
E White and blue
Romet Cable Number 34-125-40 or 34-125-41
Cable pin module wire
Corrected Uncorrected Alarm
A White and blue
B Red
C White and blue
D Red
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 71 of 91