Installation Guide

Table Of Contents
1. Remove the module backplate (4
screws) to expose the module lead wires.
The backplate and screws will be re-
installed on the module later in this
procedure so store them (temporarily) in a
safe, secure place.
2. Insert the lead wires from the module into new 3M gel connectors (Itron part number CON-0023-001)
together with the lead wire from the meter cable (see wiring connections).
3. Crimp the connectors using a 3M hand-held crimping tool.
Important! Use a crimping tool compatible with gel-connectors. Do not use a
standard pliers for crimping gel connectors. For more information, see Using
Gel-cap Connectors to Complete Wiring Connections on page 1.Follow the
correct wiring configuration for your Romet corrector or meter from the following
wiring parameters.
Standard AdEM Romet 43-035-40 Cable Wiring
Connection Corrected count Uncorrected count
Romet cable wire Romet cable wire
Pulse Output 1+ Green White Red White
Blue Blue
Pulse Output 1- White Red Black Red
Note: This wiring configuration will not allow a cut cable tamper.
Romet PG9 Pigtail Cable Wiring
Connection Corrected count
Romet cable module
Pulse Output 1+ White White
Pulse Output 1- Red Red