Installation Guide

Table Of Contents
2. Connecting the module to the corrector. Installation requires the following materials.
Connection options, Cannon cable (part number: 43-035-40*) pigtail option
Romet AdEM communication cable, available from Romet
RometLink communication software, available from Romet
3 gel cap connectors, Itron part number CON-0023-001
3M crimping tool
Torx T-10 screwdriver
Remote module with backplate and four included Torx screws (included with module)
3. Mounting the remote module (for more information, see Mounting on page 16). Select the
mounting option appropriate for your installation. Mounting options include:
Wall mount on a sheet metal surface
Pipe mount using the Itron pipe mount kit CFG-0005-003
Custom Romet mounting (see Romet documentation for custom mounting)
4. Programming the remote module. For programming information, see Programming on page
21. Programming requires an Itron programming device (for example, an FC300SR).
Romet Product Mounting Instructions
Romet ECM2 to remote module mounting option
Note: This mounting option requires a Romet mounting kit (Romet part number 34-
444-1-KIT).
1. Remove the module screw from the back of the
ECM2 meter.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 68 of 91