Romet Meter Installation
This section describes installation for Romet meters and correctors compatible with Itron remote
modules.
Meter model Meter notes Module type Itron part
number
module notes
RM Series STD CTR
600-5600
TC 2000-23000
Meter must have
factory-installed
pulser with
connector output.
Purchase cable
interface from
manufacturer.
Cellular 500G
remote module
ERG-7000-
503
RM Series
Electronically
compensated meter
ECM2 600-56000
Meter must have
connector pin with
factory-installed
pulse output.
Purchase correct
cable interface
from Romet.
AdEM Series
Correctors
including AdEM-S,
AdEM-T, and AdEM-
PTZ
Must be
configured to
350mS of output
pulse spacing and
30mS of output
pulse width.
Romet Installation Overview
Remote module installation with the Romet series correctors involves the following tasks.
1. Programming or verifying the that corrector is set up to work with the remote module.
Programming requires a computer loaded with the RometLink software and a Romet
computer-to-corrector communication cable.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation