Installation Guide

Table Of Contents
A Change Item pop-up provides the interface to
change the setting.
7. Enter the correct setting. Click Save.
8. Confirm that all settings match the settings required for the module connected to the Honeywell
Instrument. For more information, see compatible modules listed in Honeywell Instrument Installation on
page 54.
Programming the Honeywell Instrument Parameters
Program the Honeywell Instrument parameters following these Item Code Settings.
Channel A
Corrected
Volume
Channel B
UncorrectedVolume
Channel C Pulse Output Spacing
Instrunmen
t-
Pulse
Output
Options
#56 #93 #57 #94 #58 #95 #115 #1014 #1015 Terminal
Board
Connections /
Wiring
Wiring
ECAT Pulse
Board Ver-
2(3)
Form A
2 Cor
Vol
2 Unc
Vol
2 Cor
Vol
1=1.0sec
or
2=2.0sec
or
4=0.5sec
Red wire goes
to K
Blue and White
wires go to Y
Connection
must be on
same terminal
board channel
(for example,
Ka/Ya; kb/Yb;
Kc/Yc)
Ka, Ya=Channel
A
Kb, Yb=Channel
B
Kc, Yc=Channel
C
Pulse
board Ver-
3(2)
FormC1
FormA
2 Cor
Vol
Mini with
Form A main
board
Main
board
Type-2*
2 Cor
Vol
Mini-AT JB29,JB30
&JB31
Jumpered
for
FormA*
2 Cor
Vol
2 Unc
Vol
Mini-Max All main
boards
2 Cor
Vol
2 Unc
Vol
1=1.0sec
or
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation