Installation Guide

Table Of Contents
Honeywell Software Settings
1. Connect the interface cable from the Honeywell instrument to a PC loaded with the MasterLink SQL
software.
2. Open the MasterLink SQL software. The software
opens and reports a "Not Connected" status.
The Site List window automatically opens after the software detects an instrument.
3. Select the Honeywell instrument type from the Instrument List on the right of the screen.
Important! You must select the correct instrument type. Selecting the
incorrect type causes communication errors.
4. The status indicator in the lower left corner of the MasterLink SQL software displays the connection status
as Connected (instrument type).
5. To view an Item configuration, select Display > Items by Number.
6. Verify that the Honeywell instrument settings are correct. For example, Item number 56 must be set to 2.0.
If the setting is incorrect, click the Change button.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 63 of 91