Installation Guide
Table Of Contents
- Cellular 500G Module Remote Installation Guide
- Contents
- New in This Document
- 1 Important Safety and Compliance Information
- U.S. and Canadian Patent Numbers
- USA, FCC Part 15 Spectrum Compliance
- Modifications, Repairs, Installation, and Removal
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Transportation Classification
- Lithium Battery Safety
- Equipment Repairs
- Intrinsic Safety
- Electrostatic Ignition Hazard
- Module Cleaning
- Do Not Drop
- 2 About the Itron Cellular 500G Remote Module
- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Using Gel-cap Connectors to Complete Wiring Connections
- 8 Optional Sealant Application Instructions
Honeywell Software Settings
1. Connect the interface cable from the Honeywell instrument to a PC loaded with the MasterLink SQL
software.
2. Open the MasterLink SQL software. The software
opens and reports a "Not Connected" status.
The Site List window automatically opens after the software detects an instrument.
3. Select the Honeywell instrument type from the Instrument List on the right of the screen.
Important! You must select the correct instrument type. Selecting the
incorrect type causes communication errors.
4. The status indicator in the lower left corner of the MasterLink SQL software displays the connection status
as Connected (instrument type).
5. To view an Item configuration, select Display > Items by Number.
6. Verify that the Honeywell instrument settings are correct. For example, Item number 56 must be set to 2.0.
If the setting is incorrect, click the Change button.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation