Yellow Red
Blue (alarm) Blue
Channel B
TCI module wire
White White
Green Red
White Blue
7. Insert one unterminated wire into an opening of a gel-connector (six gel-connectors were included with
the TCI).
8. Insert the appropriate field cable wire into
the other gel-connector opening.
9. Verify that both wires are fully inserted into the gel-connector prior to crimping.
Important! Use a crimping tool compatible with gel-connectors. Do not use a
standard pliers for crimping gel-connects. See Using Gel-cap Connectors to
Complete Wiring Connections on page1.
10. Insert the gel-connected wires into the
threaded gray adapter plate hole.
11. Replace the strain relief and tighten until secure.
Honeywell Instrument Programming and Requirements
The Honeywell MasterLink SQL software is used to configure Honeywell products.
Important! This information is subject to change without notice. Refer to the
Honeywell MasterLink SQL product documentation to verify the most current
information about programming and configuring the corrector for use with the remote
module.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation