Ya terminal White*
*Twist the blue and white module wires together before connecting them to the Mini-Max board. Tighten the
terminal connection securely.
7. Connect the uncorrected module wires to the Input Switch Board UNC. VOL following the table below.
Uncorrected module connections
Mini-Max input switch board unc. vol. module wire color
COM terminal Red
No terminal Blue*
No terminal White*
*Twist the blue and white module wires together before connecting them to the Mini-Max board. Tighten the
terminal connection securely.
8. Tighten the large strain relief securely.
Warning! Do not crush the module through-cables when tightening the strain
relief.
9. Re-install or reconnect the power or battery sources.
10. Close the instrument case and tighten the case screw securely. Replace any locks that were removed for
installation.
11. Install the remote module. See Mounting on page 16.
Connecting to the Honeywell TCI
The Honeywell Instruments Temperature Compensating Index (TCI) provides two Form-A
volume pulse outputs and one Form-B alarm output. These outputs are electronic switches. The
Form-A pulse outputs are configurable for compensated or uncompensated volume. The Form-
B output is for alarm output use only.
Connections to the three output pulse channels are completed using loose unterminated wires
(the individual wires from a cable) and gel-connectors. The TCI unit has six unterminated wires
that require six gel-connectors (Itron part number CON-0023-001) to enable pulse connections
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation