Installation Guide

Table Of Contents
4. Strip ¼-inch individual wire insulation from the red,
white, and blue lead wires.
a. Count enabling wire (pulsed ground reference)
b. Count sensing wire (high impedance positive
reference)
c. Cut cable sensing wire (positive return)
5. Twist the blue and white wires together and connect
them to the Honeywell Instrument terminal strip connector
(Phoenix connector) following the Honeywell Instrument
Item Code Settings. For Item Code Settings, see
Programming the Honeywell Instrument Parameters on
page 64.
6. Connect the red wire following the Item Code Settings.
For Item Code Settings, see Programming the Honeywell
Instrument Parameters on page 64.
Note: In Honeywell Instrument EC-AT
correctors, the connector may be
soldered to the pulse board.
Corrected module connections
Mini-Max TB1 module wire color
K terminal Red
Ya terminal Blue*
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 59 of 91