Meter model Meter notes Module
type
Itron part
number
module notes
TCI
Temperature Compensating Index. TCI must
have a Form A board, Form C is NOT
supported. Item #56 Pulse Scaling Factor must
be 2.0. Compatible TCI firmware versions are
1.06, 1,07, and 1.10.
500G remote ERG-7000-502
ERG-7000-503
The -502 module has a
5' cable and is used
when longer cabling is
required. This module
will return the cut cable
tamper.
The -503 module has
lead wires designed for
use with the TCI
mounting bracket. This
module will return the
cut cable tamper.
Honeywell Instrument Installation Overview
Installing the remote module to a Honeywell Instrument involves the following tasks.
1. Programming the instrument and verifying that the Honeywell instrument is set up to work
with the remote module. Programming requires Honeywell software. Reference Honeywell
product and software documentation for the correct software and version requirements.
2. Installing the instrument and any required retrofit components.
3. Mounting the remote module to a pipe or flat vertical surface. For more information, (see
Mounting on page 16).
Pipe mount using the Itron pipe mount kit CFG-0005-003.
Custom Honeywell mounting using Honeywell Kit 22-1077.
Custom mounting requires three #8-32 x ½-inch screws, 3 #8 metal flat washers, and
3 rubber sealing washers.
4. Connecting the remote module to the instrument.
5. Programming the remote module. For programming information, see Programming on page
21.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 55 of 91