Installation Guide
Table Of Contents
- Cellular 500G Module Remote Installation Guide
- Contents
- New in This Document
- 1 Important Safety and Compliance Information
- U.S. and Canadian Patent Numbers
- USA, FCC Part 15 Spectrum Compliance
- Modifications, Repairs, Installation, and Removal
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Transportation Classification
- Lithium Battery Safety
- Equipment Repairs
- Intrinsic Safety
- Electrostatic Ignition Hazard
- Module Cleaning
- Do Not Drop
- 2 About the Itron Cellular 500G Remote Module
- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Using Gel-cap Connectors to Complete Wiring Connections
- 8 Optional Sealant Application Instructions
GE Oil and Gas Meter Programming and Requirements Notes
GE MeterWare software is used to configure the module's index settings.
Important! This information is subject to change without notice. Refer to the GE
MeterWare product documentation to verify the most current information about
programming and configuring the corrector for use with the remote module.
1. Open the GE Dresser MeterWare software to change the remote module settings.
2. Select the LiveData tab.
3. Confirm the firmware version and current index settings.
4. If you change a variable, click Update Values to complete the change.
5. Select the Configuration tab to view the volume configuration or confirm the volume configuration and
pulse settings. Use the drop-down lists to change the variable's setting.
Note: You must click OK to complete any setting changes.
Testing IMC or W2 Communication with GE User Terminal (UT) Communication
Software
1. Connect the IMC/W2 to the PC using the serial cable.
2. Using the GE Dresser User Terminal (UT) communications software, connect to the IMC/W2.
Read the uncorrected or corrected count number on the remote module with the Itron endpoint reading
device. Compare the IMC/W2 uncorrected or corrected amounts to those from the remote module.
4. Input approximately 20 pulses to the remote module. Verify that the uncorrected or corrected counts on the
IMC/W2 and the remote module are the same.
Programming Notes
The following table lists pulse rates for the pulse output of compatible GE indexes.
Index style Meter size
8C-11M 16M 16M-56M 1.5-11M 16M-102M
B3 CTR index 10 100
B3 TC index
(Meter built 1/1999 and beyond)
10 100
B3 TC index
(Meter built prior to 1/1999
50 500
LMMA CTR index 10 100
LMMA TC or Series 3 CTR/TC
index
100 10
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation