Installation Guide
Table Of Contents
- Cellular 500G Module Remote Installation Guide
- Contents
- New in This Document
- 1 Important Safety and Compliance Information
- U.S. and Canadian Patent Numbers
- USA, FCC Part 15 Spectrum Compliance
- Modifications, Repairs, Installation, and Removal
- Canada, ISED Spectrum Compliance
- RF Exposure (FCC/ISED)
- Transportation Classification
- Lithium Battery Safety
- Equipment Repairs
- Intrinsic Safety
- Electrostatic Ignition Hazard
- Module Cleaning
- Do Not Drop
- 2 About the Itron Cellular 500G Remote Module
- 3 Mounting
- 4 Programming
- 5 Specific Meter Manufacturer Installation
- 6 Diaphragm Meter Installation
- 7 Using Gel-cap Connectors to Complete Wiring Connections
- 8 Optional Sealant Application Instructions
Note: Use a crimping tool compatible with gel-connectors. For information about
crimping the connections, see Using Gel-cap Connectors to Complete Wiring
Connections on page1. The same process is used for wiring cables to the module.
Each meter or cable may have different wire colors and wiring instructions. See the
specific wiring configuration for your product. Wiring configurations for the B3, LMMA,
IMC/W2, MC2, ES3, and ETC meters with pulse outputs are provided in the following
information.
GE supplied cable that connects to a B3, LMMA, IMC/W2, or MC2 module
Blue Blue
White White
Red Red
Pulse output Wire Pulse output 1 only Pulse output with 1 fault
ES3 or ETC module
Output 1+ White White and blue White
Output 1- Black Red Red
Output 3+ Red White
Output 3- Green Blue
Wiring for direct connection to the IMC/W2
To receive uncorrected reads: Connect the red
wire to terminal block 3 (TB3 telemetry output) GND1
(ground) position (B). Connect the white and blue
wires to the pulse output 1 position (A).
To receive corrected reads: Connect the red wire
to the GND 2/3 (ground) TB3 telemetry output
position (C). Connect the white and blue wires to the
pulse output 2 position.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 51 of 91