Installation Guide

Table Of Contents
6. Attach the brackets to the meter using the
previously removed screws.
7. Splice the meter pulse output wires to the module wires using gel cap connectors. Follow the wire
connections for the D800/D1000 to module wire connections below.
Note: Use a crimping tool compatible with gel-connectors. Details on using the
crimping tool are included in the mounting installation section of this document.
D800/D1000 meter module
Pulse output Wire Pulse output 1 Pulse output 2 Pulse output 1
with fault
Pulse output 2
with fault
Output 1+ Brown White and blue White
Output 1- Green Red Red
Output 2+ White White and blue White
Output 2- Black Red Red
Output 3+ Red White White
Output 3- Blue Blue Blue
8. Install a cable tie strain relief on the cable
approximately 1/8" from the end of the cable
insulation.
9. Position the cable so the strain relief is just inside
the slot on the module's backplate.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 48 of 91