Installation Guide

Table Of Contents
Galvanic Gas Micro Installation
This section describes installation to Galvanic compatible correctors.
Meter model Meter notes Itron part number module notes
GasMicro Electronic
Volume Corrector
Must select 2 pulses/second
from pulse output on the
output frequency menu.
ERG-7000-503 module cut cable
requires customer-
supplied cable capable
of terminating the
module white and blue
wires at the meter
interface.
Galvanic Installation Overview
Installing the remote module to a Galvanic volume corrector involves four tasks.
1. Programming or verifying that the volume corrector is set up to work with the remote module.
Programming requires a computer communication cable.
2. Connecting the module to the volume corrector. Completing the connections requires a wire
stripper and flat-tip screwdriver sized to tighten the terminal connections on the Galvanic
corrector.
3. Mounting the remote module. Select the mounting option appropriate for your installation.
See Mounting on page 16. Mounting options include:
Wall mount on a sheet metal surface
Pipe mount using the Itron pipe mount kit CFG-0005-003
4. Programming the remote module. For programming information, see Programming on page
21. Programming requires an Itron programming device (for example, an FC300SR).
Remote module configuration with the meter is dependent on your system application. See the
Galvanic corrector product documentation for configuration information.
Galvanic Product Mounting Instructions
See the Galvanic product documentation for custom mounting instructions.
Cellular 500G Module Remote Installation Guide 5 Specific Meter Manufacturer Installation
10 March 2021 815-0622-00 REV 000 Itron, Inc. Page 40 of 91